Transcription

Implementation Service TrainingMarco RefractionEPIC WorkstationEpic-5100 Refraction System SpecificationsImplementation, Service, and TrainingUnaidedAcuitiesTo assess whether the EPIC is the best match for yourparticular needs, we perform a thorough, complimentaryanalysis of your practice. This results in specificrecommendations showing how the EPIC will improve yourprocesses and oRefractorReadingsMarco provides comprehensive, hands-on training for yourtechnicians and unmatched post-installation technical support.Such in-depth and personal training, combined with thetechnological innovation of the EPIC gives you advantagesno other technologies can provide, which directly improvesthe bottom line.SubjectiveValuesAcuities“As a solo Ophthalmologist,I had a patient flowproblem. While I hadthe patient volume, Iconstantly found myselfbacked up, which wasfrustrating to me, butmost importantly to mypatients. The MarcoEPIC Process correctedthis for me. In fact,I corrected my patientflow.and increasedit by 30%.“Marco’s online training center is available 24/7 to provideconvenient, helpful guidance for technical questions.P. Vernon Jones, MDJacksonville, FloridaMeasuring RangeSphere -29.00 to 26.75D (0.12D / 0.25D / 1D / 2D / 3D steps)Cylinder 0 to 8.75 D (0.25D / 1D / 2D / 3D steps)Axis 0 to 180 (1 / 5 / 15 steps)PD 48 to 80mm (far vision)50 to 74mm (near vision) (0.5 / 1mm steps)54 to 80mm (Far PD at which both batteries can converge)Rotary Prism 0 to 20D (0.1 / 0.5 / 2D increments) 0 – 20D (0.5D, 1D, 2D steps)Auxiliary Lenses Occluder, Polarizing Lenses, Pin Hole (1mm), 10 base-in prism, RedMaddox Horizontal (right eye), 6 base-up prism, Red Maddox Vertical(left eye), Cross mark for P.D., Red Lens (right eye), .50 fixed crosscylinder, Green Lens (left eye), Retinoscopic Lens, ( 1.5D, 2.0D)Refraction Distance for Near Vision 350 to 700mm (50mm increments)Field of View 40 (VD 12mm)39 (VD 13.75mm)Forehead Rest Adjustment 15mmVertex Distance 12-20mm (12, 13.75, 16, 18, 20mm)General InformationHorizontal Level Adjustment 2.5 Display 8.4-inch color LCD with touch screenMeasurement values areprinted out for easy evaluation.PhoriaDivergenceConvergenceNear AcuitiesNear PhoriaNear Point ofConvergenceNear Point ofAccommodationNegative RelativeAccommodationPositive RelativeAccommodation““KeratometerReadingsThe Marco EPIC and theMarco ImplementationProcess enabled me tonot only streamline mypatient flow, increasingmy throughput by 29%(profits 25%), but alsosolved the age-oldproblems of: bottleneckin the pretest area,different skill levelsof staff, turnovers,and remakes.Timothy Planty, ODHouston, TexasPower Supply 100 / 120 / 230 VAC50 / 60HzPower Consumption 120 VADimensions & WeightWxDxHMain body 15.94 x 4.0 x 10.86" / 12.8" with bracket / 7.7 lbs.Control box 8.66 x 8.1 x 7.87" / 4.2 lbs.Relay box 7.63 x 8.93 x 2.83" / 8.8 lbs.Printer 4.0 x 3.38 x 4.76" / 0.66 lbs.Epic-5100 TableRT Arm Electromagnetic lock, fully moveable up/down and back/forthDimensions & WeightW x D x HMotorized Main Table Table top: 40.35 x 19.7 x 26.77 – 33.86" (stroke 7.1")Side Table (Fixed) Table top: 42.52 x 28.46 x 29.9"Overall 42.52 x 60.7 x 61.2 – 72.83" / 352.7 lbs.Power Supply 100 / 120 / 230 VAC 10%, 50 / 60 HzPower Consumption 600 VA12.4" (W) x 20.4" (D) x 22.8" (H) 64 lbsAll automated Marco technologies share data and integratewith leading EMR programs via Marco Connect software.800.874.5274www.marco.com N153500 BR-EPIC-5100Additional information can be printed.

Epic-5100 Refraction WorkstationUnparalleled Technology and BenefitsForehead Position DetectorClear and easy-to-recognizeblue LED turns off when thepatient is properly positioned.The EPIC refraction workstation is today’s most innovative way tostreamline operations, grow your business and build your dreampractice. The EPIC decreases work-up times to less than 10 minutes,allowing the operator to perform the refraction in 3-5 minutes. Nowyou can confidently delegate data gathering to your technicians andfocus on data assessment, diagnosis and prescribing a final correction.Glare and Contrast Sensitivity(both SSC-350 MCG and SSC-370 MCG)Standardization of glare testingensures consistent and repeatableassessment of glare visual acuities,and contrast sensitivity testing aidsin cataract evaluationErgonomic Design and Wide Visual FieldThe digital refractor’s compact design ismore comfortable. Wide 40 degree field ofview provides a natural visual environmentfor more realistic, accurate measurements.From office productivity, to patient care, to the exam room, to thebottom line.the EPIC raises not only the quality of your practice,but also the quality of your life.AvailableChart OptionsEMR Integration The EPIC smoothly integrates with EMR, allowingyou to efficiently transfer data from the examination to your patientdatabase. This improves office productivity and assures a high levelof confidence in managing important patient information,with the added benefit of elimination of transcriptionerrors caused by manual data entry. ARK-1 Series Tonoref II (M3) OPD-Scan IIIAvailableLensmetersIC Card Reader The EPICcontrol console uses a data cardslot that eliminates cablingbetween instruments, providingfor quick and easy wirelessdata transfer from remote autorefractors and lensmeters.“Serves typical or wheelchair patients.5'7"ProcessTimeSavingsRetinoscopy1.5 mins.Keratometry1.5 mins.World’s First Reversible DisplaySet up refractor0.5 mins.Tiltable 8.4 inch color touch-panelLCD screen can be turned tothe patient and used as aneducational tool or preferrednear distance check.Eliminate transcription0.5 mins.Faster Work-Up TimesAutocross0.5 mins.With the EPIC, refraction has neverbeen so fast, so simple or so effective.Final verification1.5 mins.Clear out refraction0.5 mins.Prism verification1.5 mins.Total Time Saved:8.0 mins.3'7"3'5"“After purchasing a Marco RefractionWorkstation, patient data is nowcollected and then automaticallytransferred into my EMR with a touchof single button on the Marco controlpanel. Over 50 fields are automaticallypopulated without transcription errors.Lorie Lippiatt, ODSalem, Ohio LM-600 LM-600P LM-600PD LM-1800P LM-1800PDAdjustable Motorized Table“Larry Patterson, MDCrossville, TennesseeUnique operator “assist” function This unique feature offers operationand question guidance for examinations, making it possible for thetechnician to provide smooth and accurate exams. SSC-370 MCG SSC-350 MCGAvailableAutorefractorsEPIC Refractions in Half the Space: The highly advanced EPICrefraction workstation is both user and patient friendly. The workstationcan be configured to combine technologies such as a digital refractor,an auto refractor/keratometer (with or without tonometry), orOPD-Scan III on a motorized table, a space-saving chart projector,and auto lensmeter. The EPIC uses half the space of a traditional lane,requiring an area of only five-by-six feet, allowing you to free up roomsfor other procedures. The EPIC delivers the tools your technicians needto directly increase office productivity and patient flow. Integrates wavefront data into subjective refraction (OPD-Scan III option) Works with wireless data card communications Auto-maintains proper convergence at variable near-working distances Shares data between multiple instruments Offers adjustable table and counterbalanced arm Prints hard copies to an external printerWith 7 doctors and 18 technicians,I was always struggling to find a wayfor everyone to provide consistentrefraction results, and for those resultsto be accurate. After implementingthe Marco EPIC with OPD-Scan III,my problems were solved. The EPICrefraction sequence and the additionof the OPD-Scan III to the EPIC takesaccuracy to a whole new level.“Save Time for What’s Most Important: Today’s health care environmentdemands effective use of your resources to increase operational efficiency,without compromising patient care, to maximize productivity. The EPICrefraction workstation from Marco helps you do just that.Imagine Your Life Just Got Easier: Diagnostic decisions are faster, yetmore precise than ever. Patient throughput has increased by 50-75%and patient satisfaction has never been higher. And you have more timeto spend as you like, for personal leisure or patient care. Meanwhile,your staff is more efficient and profits increase.User FriendlyIntelligent Custom ConfigurationsManual Workup. 15 mins.EPIC Workup. 7 mins.Marco’s EPIC workstation hasempowered the staff by allowing themto do more with patients. Techniciansconduct all the pre-testing and Icomplete the refracting process with thepatient. Typically, finalizing the refractionnow saves me several minutes per patientand allows extra time to talk about lenschoices and visual needs.“Fast“AccurateDori Carlson, ODPark River & Grafton, North Dakota

Epic-5100 Refraction WorkstationUnparalleled Technology and BenefitsForehead Position DetectorClear and easy-to-recognizeblue LED turns off when thepatient is properly positioned.The EPIC refraction workstation is today’s most innovative way tostreamline operations, grow your business and build your dreampractice. The EPIC decreases work-up times to less than 10 minutes,allowing the operator to perform the refraction in 3-5 minutes. Nowyou can confidently delegate data gathering to your technicians andfocus on data assessment, diagnosis and prescribing a final correction.Glare and Contrast Sensitivity(both SSC-350 MCG and SSC-370 MCG)Standardization of glare testingensures consistent and repeatableassessment of glare visual acuities,and contrast sensitivity testing aidsin cataract evaluationErgonomic Design and Wide Visual FieldThe digital refractor’s compact design ismore comfortable. Wide 40 degree field ofview provides a natural visual environmentfor more realistic, accurate measurements.From office productivity, to patient care, to the exam room, to thebottom line.the EPIC raises not only the quality of your practice,but also the quality of your life.AvailableChart OptionsEMR Integration The EPIC smoothly integrates with EMR, allowingyou to efficiently transfer data from the examination to your patientdatabase. This improves office productivity and assures a high levelof confidence in managing important patient information,with the added benefit of elimination of transcriptionerrors caused by manual data entry. ARK-1 Series Tonoref II (M3) OPD-Scan IIIAvailableLensmetersIC Card Reader The EPICcontrol console uses a data cardslot that eliminates cablingbetween instruments, providingfor quick and easy wirelessdata transfer from remote autorefractors and lensmeters.“Serves typical or wheelchair patients.5'7"ProcessTimeSavingsRetinoscopy1.5 mins.Keratometry1.5 mins.World’s First Reversible DisplaySet up refractor0.5 mins.Tiltable 8.4 inch color touch-panelLCD screen can be turned tothe patient and used as aneducational tool or preferrednear distance check.Eliminate transcription0.5 mins.Faster Work-Up TimesAutocross0.5 mins.With the EPIC, refraction has neverbeen so fast, so simple or so effective.Final verification1.5 mins.Clear out refraction0.5 mins.Prism verification1.5 mins.Total Time Saved:8.0 mins.3'7"3'5"“After purchasing a Marco RefractionWorkstation, patient data is nowcollected and then automaticallytransferred into my EMR with a touchof single button on the Marco controlpanel. Over 50 fields are automaticallypopulated without transcription errors.Lorie Lippiatt, ODSalem, Ohio LM-600 LM-600P LM-600PD LM-1800P LM-1800PDAdjustable Motorized Table“Larry Patterson, MDCrossville, TennesseeUnique operator “assist” function This unique feature offers operationand question guidance for examinations, making it possible for thetechnician to provide smooth and accurate exams. SSC-370 MCG SSC-350 MCGAvailableAutorefractorsEPIC Refractions in Half the Space: The highly advanced EPICrefraction workstation is both user and patient friendly. The workstationcan be configured to combine technologies such as a digital refractor,an auto refractor/keratometer (with or without tonometry), orOPD-Scan III on a motorized table, a space-saving chart projector,and auto lensmeter. The EPIC uses half the space of a traditional lane,requiring an area of only five-by-six feet, allowing you to free up roomsfor other procedures. The EPIC delivers the tools your technicians needto directly increase office productivity and patient flow. Integrates wavefront data into subjective refraction (OPD-Scan III option) Works with wireless data card communications Auto-maintains proper convergence at variable near-working distances Shares data between multiple instruments Offers adjustable table and counterbalanced arm Prints hard copies to an external printerWith 7 doctors and 18 technicians,I was always struggling to find a wayfor everyone to provide consistentrefraction results, and for those resultsto be accurate. After implementingthe Marco EPIC with OPD-Scan III,my problems were solved. The EPICrefraction sequence and the additionof the OPD-Scan III to the EPIC takesaccuracy to a whole new level.“Save Time for What’s Most Important: Today’s health care environmentdemands effective use of your resources to increase operational efficiency,without compromising patient care, to maximize productivity. The EPICrefraction workstation from Marco helps you do just that.Imagine Your Life Just Got Easier: Diagnostic decisions are faster, yetmore precise than ever. Patient throughput has increased by 50-75%and patient satisfaction has never been higher. And you have more timeto spend as you like, for personal leisure or patient care. Meanwhile,your staff is more efficient and profits increase.User FriendlyIntelligent Custom ConfigurationsManual Workup. 15 mins.EPIC Workup. 7 mins.Marco’s EPIC workstation hasempowered the staff by allowing themto do more with patients. Techniciansconduct all the pre-testing and Icomplete the refracting process with thepatient. Typically, finalizing the refractionnow saves me several minutes per patientand allows extra time to talk about lenschoices and visual needs.“Fast“AccurateDori Carlson, ODPark River & Grafton, North Dakota

Epic-5100 Refraction WorkstationUnparalleled Technology and BenefitsForehead Position DetectorClear and easy-to-recognizeblue LED turns off when thepatient is properly positioned.The EPIC refraction workstation is today’s most innovative way tostreamline operations, grow your business and build your dreampractice. The EPIC decreases work-up times to less than 10 minutes,allowing the operator to perform the refraction in 3-5 minutes. Nowyou can confidently delegate data gathering to your technicians andfocus on data assessment, diagnosis and prescribing a final correction.Glare and Contrast Sensitivity(both SSC-350 MCG and SSC-370 MCG)Standardization of glare testingensures consistent and repeatableassessment of glare visual acuities,and contrast sensitivity testing aidsin cataract evaluationErgonomic Design and Wide Visual FieldThe digital refractor’s compact design ismore comfortable. Wide 40 degree field ofview provides a natural visual environmentfor more realistic, accurate measurements.From office productivity, to patient care, to the exam room, to thebottom line.the EPIC raises not only the quality of your practice,but also the quality of your life.AvailableChart OptionsEMR Integration The EPIC smoothly integrates with EMR, allowingyou to efficiently transfer data from the examination to your patientdatabase. This improves office productivity and assures a high levelof confidence in managing important patient information,with the added benefit of elimination of transcriptionerrors caused by manual data entry. ARK-1 Series Tonoref II (M3) OPD-Scan IIIAvailableLensmetersIC Card Reader The EPICcontrol console uses a data cardslot that eliminates cablingbetween instruments, providingfor quick and easy wirelessdata transfer from remote autorefractors and lensmeters.“Serves typical or wheelchair patients.5'7"ProcessTimeSavingsRetinoscopy1.5 mins.Keratometry1.5 mins.World’s First Reversible DisplaySet up refractor0.5 mins.Tiltable 8.4 inch color touch-panelLCD screen can be turned tothe patient and used as aneducational tool or preferrednear distance check.Eliminate transcription0.5 mins.Faster Work-Up TimesAutocross0.5 mins.With the EPIC, refraction has neverbeen so fast, so simple or so effective.Final verification1.5 mins.Clear out refraction0.5 mins.Prism verification1.5 mins.Total Time Saved:8.0 mins.3'7"3'5"“After purchasing a Marco RefractionWorkstation, patient data is nowcollected and then automaticallytransferred into my EMR with a touchof single button on the Marco controlpanel. Over 50 fields are automaticallypopulated without transcription errors.Lorie Lippiatt, ODSalem, Ohio LM-600 LM-600P LM-600PD LM-1800P LM-1800PDAdjustable Motorized Table“Larry Patterson, MDCrossville, TennesseeUnique operator “assist” function This unique feature offers operationand question guidance for examinations, making it possible for thetechnician to provide smooth and accurate exams. SSC-370 MCG SSC-350 MCGAvailableAutorefractorsEPIC Refractions in Half the Space: The highly advanced EPICrefraction workstation is both user and patient friendly. The workstationcan be configured to combine technologies such as a digital refractor,an auto refractor/keratometer (with or without tonometry), orOPD-Scan III on a motorized table, a space-saving chart projector,and auto lensmeter. The EPIC uses half the space of a traditional lane,requiring an area of only five-by-six feet, allowing you to free up roomsfor other procedures. The EPIC delivers the tools your technicians needto directly increase office productivity and patient flow. Integrates wavefront data into subjective refraction (OPD-Scan III option) Works with wireless data card communications Auto-maintains proper convergence at variable near-working distances Shares data between multiple instruments Offers adjustable table and counterbalanced arm Prints hard copies to an external printerWith 7 doctors and 18 technicians,I was always struggling to find a wayfor everyone to provide consistentrefraction results, and for those resultsto be accurate. After implementingthe Marco EPIC with OPD-Scan III,my problems were solved. The EPICrefraction sequence and the additionof the OPD-Scan III to the EPIC takesaccuracy to a whole new level.“Save Time for What’s Most Important: Today’s health care environmentdemands effective use of your resources to increase operational efficiency,without compromising patient care, to maximize productivity. The EPICrefraction workstation from Marco helps you do just that.Imagine Your Life Just Got Easier: Diagnostic decisions are faster, yetmore precise than ever. Patient throughput has increased by 50-75%and patient satisfaction has never been higher. And you have more timeto spend as you like, for personal leisure or patient care. Meanwhile,your staff is more efficient and profits increase.User FriendlyIntelligent Custom ConfigurationsManual Workup. 15 mins.EPIC Workup. 7 mins.Marco’s EPIC workstation hasempowered the staff by allowing themto do more with patients. Techniciansconduct all the pre-testing and Icomplete the refracting process with thepatient. Typically, finalizing the refractionnow saves me several minutes per patientand allows extra time to talk about lenschoices and visual needs.“Fast“AccurateDori Carlson, ODPark River & Grafton, North Dakota

Implementation Service TrainingMarco RefractionEPIC WorkstationEpic-5100 Refraction System SpecificationsImplementation, Service, and TrainingUnaidedAcuitiesTo assess whether the EPIC is the best match for yourparticular needs, we perform a thorough, compliment