"Enter g--Directrgy Operuations,&efomnceRimrvermen tatoTodd BrumfieldDirector, Regulatory & PerformanceImprovementRBG-47605August 20, 2015U.S. Nuclear Regulatory CommissionAttn: Document Control DeskWashington, DC 20555SUBJECT:Application for Technical Specification Changes for Technical SpecificationTask Force (TSTF) Improved Standard Technical Specification ChangeTraveler, TSTF-523, "Generic Letter 2008-01, Managing Gas Accumulation"-SupplementRiver Bend Station, Unit 1Docket No. 50-458License No. NPF-47Reference1. Entergy Letter; Application for Technical Specification Changes TechnicalSpecification Task Force (TSTF) Improved Standard Technical SpecificationChange Traveler, TSTF-523, "Generic Letter 2008-01, Managing GasAccumulation" (RBG-47497) Dated September 2, 20142. NRC email; River Bend Station, Unit 1, Request for Additional InformationRegarding TSTF-523 (TAC No. MF4782), Dated March 27, 20153. Entergy Letter; Response to Request for Additional Information onApplication for TSTF-523, "Generic Letter 2008-01, Managing GasAccumulation," (RBG-47557) Dated April 28, 2015Dear Sir or Madam:In Reference 1, Entergy Operations, Inc. (Entergy) submitted a request for an amendment.to the Technical Specifications (TS) for River Bend Station (RBS), Unit 1. The proposedamendment modifies the existing Surveillance Requirements (SRs) related to gasaccumulation for the Emergency Core Cooling Systems (ECCS). This request was basedupon Technical Specification Task Force (TSTF) Improved Standard TechnicalSpecification Change Traveler, TSTF-523, "Generic Letter 2008-01, Managing GasAccumulation."This initial submittal contained markups of the proposed specifications which were not infinal form.Ai -

RBG-47605Page 2 of 3In Reference 3 in a response to an NRC Staff request for additional information (RAl),RBS determined the notes to specifications SR 3.4.9.2 and SR 3.4.10.2 were no longerrequired. Revised markups of these pages were not included in that submittal.Attachment 1 provides the final technical specification pages. There are no newcommitments in this letter, If you have any questions or require additional information,please contact Mr. J. A. Clark at (225) 381-4177.I declare under penalty of perjury that the foregoing is true and correct, executed onAugust 20, 2015.NTB/JAC/bm bAttachments:1.Final Technical Specification Pagescc: Regional AdministratorU. S. Nuclear Regulatory Commission, Region IV1600 East Lamar Blvd.Arlington, TX 76011-4511SNRC Senior Resident InspectorP. 0. Box 1050St. Francisville, LA 70775U. S. Nuclear Regulatory CommissionAttn: Mr. Alan WangMS O-8B1One White Flint North11555 Rockville PikeRockville, MD 20852Department of Environmental QualityOffice of Environmental ComplianceRadiological Emergency Planning and Response SectionJi Young WileyP.O. Box 4312Baton Rouge, LA 70821-4312

RBG-47605Page 3 of 3Public Utility Commission of TexasAttn: PUC Filing Clerk1701 N. Congress AvenueP. 0. Box 13326Austin, TX 78711-3326RBF1-15-0133LAR 2014-04

Attachment 1RBG-47605Final Technical Specification PagesSpecificationPage3.4.93.4.103.5.13.5.23.4 -243.4 -263.5 -43.5-83.5.33.6.2.33.9.83.5 - 113.6 - 383.9 - 113.9.93.9- 13

RHR Shutdown Cooling System - Hot Shutdown3.4.9SURVEILLANCE REQUIREMENTSFREQUENCYSURVEILLANCESR 3.4.9.1-----------NOTE------------Not required to be met until 2 hours after reactorsteam dome pressure is less than the RHR cut inpermissive pressure.Verify one RHR shutdown cooling subsystem orrecirculation pump is operating.12 hoursSR 3.4.9.2-----------NOTE--------Not required to be performed until 12 hours afterreactor steam dome pressure is less than RHR cut inpermissive pressure.Verify RHR shutdown cooling subsystem locationssusceptible to gas accumulation are sufficiently filledwith water.RIVER BEND3.4-2431 daysRIVEBED 3.-24AmendmentNo. 81-, 188

RHR Shutdown Cooling System - Cold Shutdown3.4.10ACTIONS (continued)REQUIRED ACTIONCONDITIONB.No RHR shutdown coolingsubsystem in operation.B.1Verify reactor coolantcirculating by analternate method.COMPELETION TIME1 hour from discoveryof no reactor coolantcirculationANDANDNo recirculation pump inoperation.Once per 12 hoursthereafterANDB.2Monitor reactor coolanttemperature andpressure.Once per hourSURVEILLANCE REQUIREMENTSSURVEILLANCEFREQUENCYSR 3.4.10.1Verify one RHR shutdown cooling subsystem orrecirculation pump is operating.12 hoursSR 3.4.10.2Verify RHR shutdown cooling subsystem locationssusceptible to gas accumulation are sufficiently filledwith water.31 daysRIVER BEND3.4-26RIVEBED3.-26AmendmentNo. 81-, 188

ECCS - Operating, 3.5.1SURVEILLANCE REQUIREMENTSSURVEILLANCESR 3.5.1.1FREQUENCYVerify, for each ECCS injection/spray subsystem,locations susceptible to gas accumulation aresufficiently filled with water.31 days------SR 3.5.1.2-----------NOTE1. Low pressure coolant injection (LPCI)subsystems may be considered OPERABLEduring alignment and operation for decay heatremoval with reactor steam dome pressure lessthan the residual heat removal cut in .permissivepressure in MODE 3, if capable of being manuallyrealigned and not otherwise inoperable.2. Not required to be met for system vent flow pathsopened under administrative control.Verify each ECCS injection/spray subsystem manual,power operated, and automatic valve in the flow path,that is not locked, sealed, or otherwise secured inposition, is in the correct position.31 daysSR 3.5.1.3Verify ADS accumulator supply pressure isŽ 131 psig.31 daysSR 3.5.1.4Verify each ECOS pump develops the specified flowrate with the specified pump differential pressure.In accordance withthe InserviceTesting ProgramSYSTEMFLOW RATEPUMPDIFFERENTIALPRESSURELPCS 5010gpm 5050 gpm 5010gpm 282 psid 102 psid 415psidLPCIHPCS(continued)RIVER BEND3.5-4RIVERBEND.5-4AmendmentNo. 841-, 188

ECCS-- Shutdown3.5.2SURVEILLANCE REQUIREMENTS (continued)SURVEILLANCESR 3.5.2.2SR 3.5.2.3FREQUENCYVerify, for the required High Pressure Core Spray(HPCS) System, the:a.Suppression pool water level is 13 ft 3inches; orb.Condensate storage tank water level is 11 ft1 inch.Verify, for each required ECCS injection/spraysubsystem, locations susceptible to gas accumulationare sufficiently filled with water.12 hours31 daysSR 3.5.2.4--------------------NOTE-------------1. One low pressure coolant injection (LPCI)subsystem may be considered OPERABLEduring alignment and operation for decay heatremoval, if capable of being manuallyrealigned and not otherwise inoperable.2. Not required to be met for system vent flow pathsopened under administrative control.Verify each required ECCS injection/spray subsystemmanual, power operated, and automatic valve in theflow path, that is not locked, sealed, or otherwisesecured in position, is in the correct position.31 days(continued)RIVER BEND3.5-8RIVEBED35-8AmendmentNo. 84-,188

ROIC System3.5.3SURVEILLANCE REQUIREMENTSSURVEILLANCESR 3.5.3.1FREQUENCYVerify the RCIC System locations susceptible to gasaccumulation are sufficiently filled with water.31 daysSR 1Not required to be met for system vent flow pathsopened under administrative control.daysVerify each RCIC System manual, power operated,and automatic valve in the flow path, that is notlocked, sealed, or otherwise secured in position, is inthe correct position.SR 3,5.3.3--------------------NOTE--------------Not required to be performed until 12 hours afterreactor steam pressure and flow are adequate toperform the test.Verify, with RCIC steam supply pressure 1075 psigand 920 psig, the RCIC pump can develop a flowrate 600 gpm against a system head correspondingto reactor pressure.92 daysSR 3.5.3.4-----------NOTE------Not required to be performed until 12 hoursafter reactor steam pressure and flow areadequate to perform the test.Verify, with RCIC steam supply pressure 165 psigand 150 psig, the RCIC pump can develop a flowrate 600 gpm against a system head correspondingto reactor pressure.24 months(continued)RIVER BEND3.5-11RIVEBED3.-11AmendmentNo. .8!-!44-1-68, 188

RHR Suppression Pool Cooling3.6.2.3SURVEILLANCE REQUIREMENTSSURVEILLANCEFREQUENCYSR 3.6.2.3.1Verify each RHR suppression pool coolingsubsystem manual, power operated, and automaticvalve in the flow path that is not locked, sealed, orotherwise secured in position is in the correctposition or can be aligned to the correct position.31 daysSR 3.6.2.3.2Verify RHR suppression pool cooling subsystemlocations susceptible to gas accumulation aresufficiently filled with water.31 daysSR 3.6.2.3.3Verify each RHR pump develops a flow rateIn accordance 5050 gpm through the associated heatexchangers to the suppression pool.RIVER BEND3.6-38with the InserviceTesting ProgramRIVERBEND.6-38AmendmentNo. 8-4-, 188

RHR - High Water Level3.9.8ACTIONS (continued)REQUIRED ACTIONCONDITIONB.C.COMPLETION TIME-B.3------NOTEEntry and exit ispermissible underadministrative control.(continued)No RHR shutdown coolingsubsystem in operation.C.1Initiate action to closeone door in eachprimary containment airlock.ImmediatelyVerify reactor coolantcirculation by analternate method.1 hour fromdiscovery of noreactor coolantcirculationANDOnce per 12 hoursthereafterANDMonitor reactor coolanttemperature.C.2Once per hourSURVEILLANCE REQUIREMENTSSURVEILLANCEFREQUENCYSR 3.9.8.1Verify one RHR shutdown cooling subsystem isoperating.12 hoursSR 3.9.8.2Verify required RHR shutdown cooling subsystemlocations Susceptible to gas accumulation aresufficiently filled with water.31 daysRIVER BEND3.9-11RIVERBEND.9-11AmendmentNo. 841-, 188

RHR - Low Water Level3.9.9ACTIONS (continued)REQUIRED ACTIONCONDITIONB.C.COMPLETION TIMEB.2----------NOTE----Entry and exit ispermissible underadministrative control.(continued)No RHR shutdown coolingsubsystem in operation.C.1Initiate action to closeone door in eachprimary containment airlock.ImmediatelyVerify reactor coolantcirculation by analternate method.1 hour from discoveryof no reactor coolantcirculationANDOnce per 12 hoursthereafterANDMonitor reactor coolantC.2Once per hourtemperature.SURVEILLANCE REQUIREMENTSSURVEILLANCEFREQUENCYSR 3.9.9.1Verify one RHR shutdown cooling subsystem isoperating.12 hoursSR 3.9.9.2Verify required RHR shutdown cooling subsystemlocations susceptible to gas accumulation aresufficiently filled with water.31 daysRIVER BEND3.9-13RIVEBED3.-13AmendmentNo. 841, 188